Sample Set Information
ID
|
SE11
|
Title
|
Comparison of fruit metabolites among tomato varieties 2
|
Description
|
Comparison of tomato fruit metabolites. 2 caltivars (Furikoma, Micro-Tom) and 6 original species (S. peruvianum LA0372, S. pennellii LA0716, S. galapagense LA1408, S. pimpinellifolium LA1589, S. habrochaites LA1777, S. peruvianum LA3858), 3 replicates data are examined. The color of fruit of S. peruvianum and S. pennellii are green, others are red.
|
Authors
|
Takeshi Ara 1, Naoki Yamamoto 1, Kunihiro Suda 1, Tatsuya Suzuki 2, Taneaki Tsugane 2, Yoshihiko Morishita 1, Mitsuo Enomoto 1, Nozomu Sakurai 1, Hideyuki Suzuki 1, Daisuke Shibata 1, 1: Kazusa DNA Research Institute, 2: Chiba Prefectural Agriculture Research Center
|
Reference
|
Direct Submittion
|
Comment
|
version 2
|
The web resources and information related to the species used in this study are available at Plant Genome Database Japan (PGDBj).
http://pgdbj.jp/plantdb/plantinfo.html?ln=en&cmd=entry&ppid=t4081
Sample Information
ID
|
S07
|
Title
|
Solanum peruvianum LA3858 Fruit
|
Organism - Scientific Name
|
Solanum peruvianum
|
Organism - ID
|
NCBI taxonomy:4082
|
Compound - ID
|
|
Compound - Source
|
|
Preparation
|
Solanum peruvianum are grown at agricultural field in natural conditions.
|
Sample Preparation Details ID
|
|
Comment
|
[KomicMarket ID] KSBA_38
|
Analytical Method Details Information
ID
|
MS1
|
Title
|
LC-FT-ICR-MS ESI positive method 1
|
Instrument
|
Agilent1100 HPLC (Agilent), LTQ-FT (Thermo Fisher Scientific)
|
Instrument Type
|
LC-FTICR-MS
|
Ionization
|
ESI
|
Ion Mode
|
Positive
|
Description
|
Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC conditions: Agilent 1100 series (Agilent), Column: TSKgel-100V (4.6 x 250 mm, 5 micrometer; TOSOH), Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.), Gradient: (B);3 to 50% (0.0 to 20.0 min), 50 to 90% (20.0 to 40.0 min), 90% (40.0 to 45.0 min), 95% (45.1 to 50.0 min), 3% (50.1 to 57.0 min), Column temp.: 40 degree C, Flow rate=0.5mL/min, PDA: 200-650 nm (2 nm step). FT-ICR-MS conditions: Filter 1: FTMS + c norm !corona !pi res=100000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1)., Rejected mass=235.1800, 308.0000, 376.0400, 378.0300, 469.3500, 540.6100, 609.2800, 782.5700, 810.4200, 1101.7000, 1123.6800.
|
Comment_of_details
|
|
Data Analysis Details Information
ID
|
DS3
|
Title
|
PowerGet analysis for detection of all peaks (C3)
|
Description
|
Raw data files are converted to text file by MSGet software without cut off value and peaks are extracted from the text files by PowerFT with parameters (intensity cut off=5000, peak selection filter is default, intensity cut off in peak assignment=1000).
|
Comment_of_details
|
|