MS Description Extraction from sample<br /> A 10 m Extraction from sample<br /> A 10 mg sample of each dried root was weighed and homogenized in a 2-mL Eppendorf tube and 1,000 μL of a single-phase mixture of methanol/water/chloroform (5:2:2, v/v/v) containing an internal standard (ribitol, 0.4 mg/mL H2O) was added for metabolite extraction.The extraction was carried out at room temperature using mixer mills (MM 301, Verder Scientific Co. Ltd., Haan, German) at 20 Hz for 5 min.After centrifugation at 16000 ×g for 3 min at 4°C, 800 μL of the supernatant was transferred to a new 1.5-mL Eppendorf tube, to which 400 μL of distilled water was added and vortexed for 10 s. After centrifugation at 16000 ×g for 3 min at 4 °C, 400 μL of the upper layer containing hydrophilic metabolites was transferred to a new 1.5-mL Eppendorf tube, and then freeze-dried (Taitec model VD-800F freeze dryer, Taitec Co. Ltd., Saitama, Japan). For quality control samples, 10 mg of each sample was added into a 15-mL tube (total 360 mg; six biological samples and six biological replicates) and then divided into six 2-mL Eppendorf tubes such that they ontained 10 mg, 20 mg, 30 mg, 40 mg, 50 mg, and 60 mg, respectively. An empty tube was also prepared, labeled as 0 mg QC, for monitoring background effects. Metabolite extraction of these dilution series was performed sing the procedure described above.<br /> For oximation, 50 μL of methoxyamine hydrochloride in pyridine (20 mg/mL) was added and incubated at 30 °C for 90 min. For silylation, 50 μL of N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) was added and ncubated at 37 °C for 30 min. The mixture was centrifuged at 16000 ×g for 5 min at 20 °C and a 50-μL aliquot of the resultant supernatant was transferred into GC–MS vial. Each sample (1 μL) was injected into a GCMS-QP2010 Ultra instrument (Shimadzu Co., Kyoto, Japan) in split mode (25/1, v/v). Each diluted QC sample was analyzed four times from the same GC–MS vial. Analytical conditions were optimized as described in a previous study.14 The column was a fused silica capillary column (30 m × 0.25 mm i.d.) coated with 0.25 μm CP-SIL 8 CB low bleed/MS (Agilent Technologies Japan, Ltd., California, USA). The front inlet temperaturewas 230 °C, the helium gas flow rate was 1 mL/min, and the column temperature was held at 80 °C for 2 min isothermally, then raised by 15 °C/min to 330 °C, and finally held for 6 min isothermally. The transfer line and ion source temperatures were 250 °C and 200 °C, respectively. Twenty scans per second were recorded over the mass range 85–500 m/z. e recorded over the mass range 85–500 m/z.
MS ID MS1  +
MS Instrument GCMS-QP2010 Ultra, Shimazu  +
MS Ion Mode Positive  +
MS Ionization EI  +
MS Title EI and GC-MS (Quadrupole)  +
Modification dateThis property is a special property in this wiki. 23 April 2018 06:40:16  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox