Browse wiki

jump-to-nav Jump to: navigation, search
SE142:/MS2
MS Description Sixteen plants were planted on a single pl Sixteen plants were planted on a single plate separated into fourths to minimize the differences in growth conditions. Four wild-type plants were planted on one-fourth, and four bsas mutant plants were planted on each of the remaining fourths. Five plates were replicated for each bsas mutant. Each sample was extracted with a concentration of 25 mg fresh weight of tissues per microliter of the extraction medium (methanol:chloroform:water [3:1:1; v/v/v]) by using a Retsh mixer mill MM 310 at a frequency of 30 Hz−1 for 3 min at 4°C. After centrifugation for 5 min at 15,100g, 400 μL of the supernatant of each plate were put together in accordance with each section of fourths. Four hundred microliters of the 2-mL supernatant were used for GC-TOF/MS analysis, and another 400 μL were used for CE-TOF/MS analysis.<br /><br />Analysis of metabolites by CE-TOF/MS was performed using an Agilent CE capillary electrophoresis system (Agilent Technologies), an Agilent G3250AA LC/MSD TOF system (Agilent Technologies), an Agilent 1100 series binary HPLC pump, and the Agilent G1603A CE-MS adapter and Agilent G1607A CE-ESI-MS sprayer kit. Agilent G2201AA ChemStation software for CE and Analyst QS software for TOF/MS were used. For cationic compounds, separations were carried out using a fused silica capillary (50 μm i.d. × 100 cm total length) filled with 1 m formic acid as the electrolyte. The sample solutions were injected at 50 mbar for 15 s (15 nL). Prior to each run, the capillary was flushed with electrolyte for 5 min. The applied voltage was set at 30 kV. The capillary temperature was maintained at 20°C, and the sample tray was cooled below 4°C. Fifty percent (v/v) methanol-water containing 0.5 μm reserpine was delivered as the sheath liquid at 10 μL min−1. ESI-TOF/MS was conducted in the positive ion mode and the capillary voltage was set at 4 kV. A flow rate of heated dry nitrogen gas (heater temperature 300°C) was maintained at 10 psig. In TOF/MS, the fragmentor, skimmer, and Oct RFV voltage were set at 110, 50, and 160 V, respectively. In acquiring a fragment ion mass spectrum, the fragmentor voltage was increased to 210 V. Automatic recalibration of each acquired spectrum was performed using reference masses of reference standards. The methanol dimer ion ([2M + H]+; m/z 65.0597) and reserpine ([M + H]+; m/z 609.2806) provided the lock mass for exact mass measurements. Exact mass data were acquired at a rate of 1.5 cycles s−1 over a 50 to 1,000 m/z range. Analysis of anionic compounds and nucleotides was carried out as described previously (Soga et al., 2002a, 2002b). ed previously (Soga et al., 2002a, 2002b).
MS ID MS2  +
MS Instrument CE:Agilent CE capillary electrophoresis system (Agilent Technologies)<br />TOF-MS:Agilent G3250AA LC/MSD TOF system (Agilent Technologies)<br />CE-MS:Agilent G1603A  +
MS Ion Mode Positive  +
MS Ionization ESI  +
MS Title CE-TOF/MS  +
Modification dateThis property is a special property in this wiki. 11 April 2018 06:54:31  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox