SE145:/MS3
MS Description Extraction for LC-q-TOF-MS to detect lipid Extraction for LC-q-TOF-MS to detect lipids<br /> Each frozen samplewas milled using mixer mill MM301 (Retsch) at a frequency of 20 Hz for 2 min at 4°C. After that, frozen powder was extracted with 20 fold volume of extraction solvent (chloroform/methanol/waer[50 : 100 : 31.45, v/v])containing 0.25mM of 1,2-dioctanoyl-sn-glycero-3-phosphocholine (SIGMA). Samples were vigorously mixed using a vortex mixture. 52.5 μl of water and 52.5 μl of chloroform were added to 200 μl of extract and then vigorously mixed for 5 min at room temperature. After standing for 15 min on ice, the samples were centrifuged at 1,000 ×g at 5°C for 5 min. The supernatant (85 μl) was transferred to a 2 ml tube with insert. Each extract was evaporated to dryness by SPD2010 SpeedVac® concentrator (Thermo Fisher Scientific). The residue was dissolved in 162μl of ethanol, and centrifuged at 10,000×g at 45°C for 15 min. Two hundred microliter of the supernatant was transferred to a glass tube for lipid analysis.<br /><br /> LC-q-TOF-MS conditions to detect lipids<br /> Sample extracts (1 μl) were analyzed using an LC-MS system equipped with an electrospray ionization (ESI) interface (HPLC, Waters Acquity UPLC system; MS, Waters Xevo G2 Qtof). Two-solvent (A and B) system was used for separation of each metabolite. Compositions of these solvents were as follows: solvent A, acetonitrile: water:1 M ammonium acetate:formic acid = (158 g:800g:10 ml:1 ml); solvent B, acetonitrile:2-propanol:water:1 M ammonium acetate:formic acid = (79 g:711 g:10 ml:1 ml). The analytical conditions were as follows. HPLC: column, Acquity UPLC HSS T3 (pore size 1.8 μm, 1.0 i.d × 50 mm long, Waters); gradient program, 35% B at 0 min, 70% B at 3 min, 85% B at 7 min, 90% B at 10 min, 90% B at 12 min and 35% B at 12.5 min; flow rate, 0.15 ml/min; temperature, 55°C; MS detection: capillary voltage, +3.0 kV; cone voltage, 20 V for positive mode and 40 V for negative mode; source temperature, 120°C; desolvation temperature, 450°C; cone gas flow, 50 l/h; desolvation gas flow, 450 l/h; collision energy, 6 V; detection mode, scan (m/z 100–2000; scan time, 0. 5 sec; centroid). The scans were repeated for 15 min in a single run. The data were recorded using MassLynx version 4.1 software (Waters). ng MassLynx version 4.1 software (Waters).
MS ID MS3  +
MS Instrument HPLC, Waters Acquity UPLC system; MS, Waters Xevo G2 Qtof  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive  +
MS Ionization ESI  +
MS Title LC-q-TOF-MS (to detect lipids)  +
Modification dateThis property is a special property in this wiki. 12 April 2018 06:58:59  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox