Browse wiki

jump-to-nav Jump to: navigation, search
SE158:/MS1
MS Description Extraction of Metabolites<br /> The Extraction of Metabolites<br /> The samples were extracted with 50 μL of 80% MeOH per mg dry weight using a mixer mill (MM300, Retsch) with zirconia beads for 10 min at 20 Hz and 4°C. After centrifugation for 10 min, the supernatant was filtered using an HLB μElution plate (Waters).<br /> <br /> LC–FTICR–MS/MS Analysis<br /> The solutions (5 μL) were analyzed using an LC–FTICR–MS instrument (LC, Agilent 1260 Infinity; MS, Bruker Daltonics SolariX 7.0 T). Analytical conditions were as follows. LC: column, Xselect CSH Phenyl-Hexyl (3.5 μm, 2.1 mm × 150 mm, Waters, Milford, MA, USA); solvent system, solvent A (water with 0.1% formic acid) and solvent B (acetonitrile with 0.1% formic acid); LC gradient program, 99.5% A/0.5% B at 0 min, 0.5% A/99.5% B at 30.0 min, 0.5% A/99.5% B at 45.0 min, 99.5% A/0.5% B at 45.1 min, and 99.5% A/0.5% B at 60.0 min; flow rate, 0.3 mL/min; column temperature, 35°C; wavelength, 200–600 nm; MS/MS detection; Acquisition Mass Control (mass range, m/z 100–600; estimated resolution power, 66,000 at m/z 400; transient length, 0.4893); Data Storage, save full profile spectrum, on; save FID file, on; Accumulation (average scan, 1; source accumulation, 0 s; ion accumulation time, 0.1 s; ion cooling time, 0 s; time of flight, 0.4 s); API Source [source type, electrospray ionization (ESI); capillary, 4500 V; end plate offset, -500 V]; Source Gas Tune (nebulizer 1.6 bar; dry gas, 7.0 L/min; dry temperature, 200°C); Source Optics (capillary exit, 220 V; deflector plate, 200 V; funnel 1, 150 V; skimmer 1, 25 V; funnel RF amplitude, 150 Vpp); Octopole (frequency, 5 MHz; RF amplitude, 350 Vpp); Collision Cell (collision voltage, -2 V; DC extract bias, 0.4 V polarity, RF frequency, 2 MHz; collision RF amplitude, 1200 Vpp); Transfer Optics (time of flight, 0.4 ms; frequency, 6 MHz, RF amplitude, 350 Vpp); Infinity Cell (transient exit lens, -20 V; analyzer entrance, -10 V; side kick, 0 V; side kick offset, -1.5 V; front trap plate, 0.6 V; back trap plate, 0.6 V; sweep excitation power, 18%); Multiple Cell Accumulations (number of ICR cell fills, 1); Gated Trapping (gated trapping mode, off); Precursor Selection (prefer list, m/z of target compound [M + H]+, mass accuracy, ±20 ppm; exclude unknown charged ions, on); Quadrupole Parameters (MS/MS isolation, on; cut off in MS, m/z 100; isolation window, m/z 5); Fragmentation Mode, quadrupole collision-induced dissociation (QCID); MS/MS Boost, on (in use); MS accumulation in MS/MS Boost, 0.1 s (in use); MS/MS accumulation in MS/MS Boost, 2 s (in use); fixed collision voltage, 30 V; polarity, positive; API high voltage, on; source quench, on. ; API high voltage, on; source quench, on.
MS ID MS1  +
MS Instrument LC, Agilent 1260 Infinity; MS, Bruker Daltonics SolariX 7.0 T  +
MS Instrument Type LC-FTICR-MS  +
MS Ion Mode Positive  +
MS Ionization ESI  +
MS Title LC–FTICR–MS/MS  +
Modification dateThis property is a special property in this wiki. 23 April 2018 05:06:54  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox