SE166:/MS01
MS Description Fresh samples were extracted with 5 μl of Fresh samples were extracted with 5 μl of 80% MeOH containing 2.5 µM lidocaine and 10-camphor sulfonic acid per mg fresh weight using a mixer mill with zirconium beads for 7 min at 18 Hz and 4 °C. After centrifugation for 10 min, the supernatant was filtered using an HLB μElution plate (Waters). The extracts (1 μl) were analyzed using LC-QTOF-MS (LC, Waters Acquity UPLC system; MS, Waters Xevo G2 Q-Tof). Analytical conditions were as follows: LC column, Acquity bridged ethyl hybrid (BEH) C18 (1.7 μm, 2.1 mm × 100 mm, waters); solvent system, solvent A [water including 0.1% (v/v) formic acid] and solvent B [acetonitrile including 0.1% (v/v) formic acid]; gradient program, 90% A/10% B at 0 min, 90% A/10% B at 0.1 min, 80% A/20% B at 25 min, 0% A/100% B at 25.1 min, 0% A/100% B at 27.5 min, 90% A/10% B at 27.6 min and 90% A/10% B at 30.0 min; flow rate, 0.3 ml/min; column temperature, 40 °C; photodiode array, 200–500 nm; flavonoid detection, 320 nm; MS detection: capillary voltage, + 3.0 keV, cone voltage, 25.0 V, source temperature, 120 °C, desolvation temperature, 450 °C, cone gas flow, 50 l/h; desolvation gas flow, 800 l/h; collision energy, 6 V; mass range, m/z 50‒2000; scan duration, 1.0 s; inter-scan delay, 0.014 s; data acquisition, centroid mode; polarity, positive; Lockspray (leucine enkephalin): scan duration, 1.0 s; inter-scan delay, 0.1 s. MS/MS data were acquired in the ramp mode in the following analytical conditions: (1) MS: mass range, m/z 50–1500; scan duration, 1.0 s; inter-scan delay, 0.014 s; data acquisition, centroid mode; and (2) MS/MS: mass range, m/z 50–1500; scan duration, 0.1 s; inter-scan delay, 0.014 s; data acquisition, centroid mode; collision energy, ramped from 10 to 50 V. In this mode, MS/MS spectra of the top 10 ions (> 10,000 counts) in an MS scan were automatically obtained. If the ion intensity was less than 10,000, MS/MS data acquisition was not performed and moved to the next top 10 ions. rformed and moved to the next top 10 ions.
MS ID MS01  +
MS Instrument LC, Waters Acquity UPLC system; MS, Waters Xevo G2 Q-Tof  +
MS Ion Mode positive  +
MS Ionization ESI  +
MS Title Flavonoid profiling by UPLC/PDA/QTOF/MS  +
Modification dateThis property is a special property in this wiki. 11 May 2018 07:13:32  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox