SE189:/MS1
MS Description Sample Preparation<br /> Thirty 1-we Sample Preparation<br /> Thirty 1-week-old plants were frozen in liquid N2 and ground to powder, which was used for methanol extraction. The extracts were filtered through disposable membrane filter units (DISMIC-13JP, ADVANTEC), evaporated under N2 atmosphere, and stored at −80°C until use. Upon FT-ICR/MS analysis, the extracts were dissolved in 50% (v/v) acetonitrile/water. IMCs for the positive ion mode were lidocaine ([M + H]+ = 235.18049), prochloraz ([M + H]+ = 376.03809), reserpine ([M + H]+ = 609.28066), and bombesin ([M + 2H]2+ = 810.41481). A set of 2,4-dichlorophenoxy acetic acid ([M−H]− = 218.96212), ampicillin ([M−H]− = 348.10235), 3-[(3-cholamidopropyl) dimethylammonio] propanesulfonic acid ([M−H]− = 613.38920), and tetra-N-acetylchitotetraose ([M−H]− = 829.32078) were used as the IMCs in the negative ion mode analysis. <br /><br /> FT-ICR/MS Conditions<br /> Mass analysis was done using an IonSpec Explorer FT-ICR/MS (IonSpec) equipped with a 7-tesla actively shielded superconducting magnet. Ions were generated from an ESI source with a fused silica needle of 0.005-inch i.d. Samples were infused using a Harvard syringe pump model 22 at a flow rate of 0.5 to 1.0 μL min−1 through a 100-μL Hamilton syringe. All the experimental events were controlled using Omega8 software (IonSpec). Briefly, the potentials on the electrospray emitters were set to 3.0 kV and −3.0 kV for the positive and the negative electrosprays, respectively. The base pressure in the source region was approximately 5 × 10−5 torr (1 torr = 133.3 Pa). For the positive and negative electrosprays, sample solutions were prepared in 50% (v/v) acetonitrile/water with 0.1% (v/v) of formic acid and ammonium hydroxide, respectively. Ionized metabolites were accumulated for a period of 2,500 to 5,000 ms in a hexapole ion trap/guide and transferred through a radiofrequency-only quadrupole into the FT-ICR cell in the superconducting magnetic field, where they were again trapped. The direct current potentials in the positive and negative ion mode analyses were −2 V and 2 V during the ion accumulation and 2 V and −2 V for the ion transfer into the FT-ICR cell, respectively. These ions trapped in the hexapole were extracted for the transfer into the FT-ICR cell. In the positive and negative ion modes, the potentials on the extraction plate were 12 V and −12 V during the ion trapping and were reversed to −2 V and 2 V for the extraction. The base pressure in the analyzer region was set to the level of approximately 4 × 10−10 torr. ESI-MS spectra were acquired over the m/z range 55 to 1,000 from 1,024,000 independent data points. MS/MS analyses were done using the sustained off-resonance irradiation SORI-CID methods (Gauthier et al., 1991; Laskin and Futrell, 2005). SORI Rf was set at 0.5 to 1.5 V, and the N2 collision gas was used with 400-ms pulse. collision gas was used with 400-ms pulse.
MS ID MS1  +
MS Instrument IonSpec Explorer FT-ICR/MS (IonSpec)  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title FT-ICR/MS  +
Modification dateThis property is a special property in this wiki. 18 May 2018 04:58:29  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox