MS Description Methanol, isopropanol, and acetonitrile of Methanol, isopropanol, and acetonitrile of LC-MS grade were purchased from Wako. Ammonium acetate and EDTA were purchased from Wako and Dojindo, respectively. Milli-Q water was purchased from Millipore. <LC Method> The LC system consisted of a Bruker Elute UHPLC system. Lipids were separated on an Acquity UPLC Peptide BEH C18 column (50 x 2.1 mm; 1.7 µm) (Waters, Milford, MA, USA). The column was maintained at 45°C at a flow-rate of 0.3 mL/min. The mobile phases consisted of (A) 1:1:3 (v/v/v) acetonitrile:methanol:water with ammonium formate (5 mM) and 10 nM EDTA and (B) 100% isopropanol with ammonium formate (5 mM) and 10 nM EDTA. A sample volume of 0.5-3 µL, which depended on biological samples, was used for the injection. The separation was conducted under the following gradient: 0 min 0% (B); 1 min 0% (B); 5 min 40% (B); 7.5 min 64% (B); 12 min 64% (B); 12.5 min 82.5% (B); 19 min 85% (B); 20 min 95% (B); 20.1 min 0% (B); and 25 min 0% (B). Sample temperature was maintained at 4°C. <MS Method> Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). Data dependent MS/MS acquisition (DDA) was used. The parameters were MS1 mass ranges, m/z 200-2500 and MS2 mass ranges, m/z 50-2500; MS1 cycle time, 0.5 sec; MS2 accumulation 14 Hz ; collision energy, 30 eV; end plate offset, 500 V; capillary voltage, +4.5 kV/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 10.0 l/min; dry temperature, 220°C/200°C; funnel 1 RF, 300 Vpp; funnel 2 RF, 200 Vpp/250 Vpp; multipole RF, 200 Vpp; deflection delta, +70 V/-70 V; quadrupole ion energy, 6 eV/5 eV; collision transfer energy, 14 eV/15 eV; collision RF, 1100 to 1800 Vpp stepping; transfer time 45 to 75 µs stepping; pre-pulse storage, 10 µs/5 µs; intensity threshold, 31cts.; exclusion time of precursor ion, 0.2 min. The mass calibration was automatically performed using 5 mM sodium acetate calibration solution. 5 mM sodium acetate calibration solution.
MS ID MS05  +
MS Instrument LC, Bruker Elute UHPLC system; MS, Bruker timsTOF Pro  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title Method 5: Bruker timsTOF Pro DDA for mouse tissue lipidomics  +
Modification dateThis property is a special property in this wiki. 26 December 2019 06:23:02  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox