SE196:/MS08
MS Description Water, isopropanol, and acetonitrile were Water, isopropanol, and acetonitrile were purchased from Fisher Optima. Methanol was purchased from J.T. Baker. Ammonium formate, ammonium acetate, formic acid, and methyl tert-butyl ether (MTBE) were purchased from Sigma-Aldrich. Odd chain and deuterated lipids used as internal standards were purchased from Avanti Polar Lipids, CDN Isotopes, Cayman Chemical, and Sigma-Aldrich. <LC Method> The LC system consisted of an Agilent 1290 system (Agilent Technologies Inc.) with a pump (G4220A), a column oven (G1316C), and an autosampler (G4226A). Lipids were separated on an Acquity UPLC CSH C18 column (100 x 2.1 mm; 1.7 µm) coupled to an Acquity UPLC CSH C18 VanGuard precolumn (5 x 2.1 mm; 1.7 µm) (Waters, Milford, MA, USA). The column was maintained at 65°C at a flow-rate of 0.6 mL/min. For LC-ESI(+)-MS analysis the mobile phases consisted of (A) 60:40 (v/v) acetonitrile:water with ammonium formate (10 mM) and formic acid (0.1%) and (B) 90:10:0.1 (v/v/v) isopropanol:acetonitrile:water with ammonium formate (10 mM) and formic acid (0.1%). For LC-ESI(-)-MS analysis the organic solvents for mobile phases were the same with the exception of using ammonium acetate (10 mM) as mobile-phase modifier. A sample volume of 3 µL was used for the injection in both ESI(+) and ESI(-). The separation was conducted under the following gradient in ESI(+): 0 min 15% (B); 0-2 min 30% (B); 2-2.5 min 48% (B); 2.5-11 min 82% (B); 11-11.5 min 99% (B); 11.5-12 min 99% (B); 12-12.1 min 15% (B); and 12.1-15 min 15% (B). The separation was conducted under the following gradient in ESI(-): 0 min 15% (B); 0-2 min 30% (B); 2-2.5 min 48% (B); 2.5-9.5 min 76%; 9.5-9.6 min 99% (B); 9.6-10.5 min 99% (B); 10.5-10.6 min 15% (B); 10.6-13.5 min 15% (B). Sample temperature was maintained at 4°C. <MS Method> Mass spectrometric detection of lipids was performed on a quadrupole/time-of-flight mass spectrometer TripleTOF 6600 (SCIEX, Framingham, MA, USA). All analyses were performed at the high resolution mode in MS1 (~35,000 full width at half maximum (FWHM)) and at the high sensitivity mode (~15,000 FWHM) in MS2. For ESI(+), the SWATH parameters were MS1 accumulation time, 100 ms; MS1 mass range, m/z 100-1700; MS2 accumulation time, 10 ms; collision energy, 45 eV; collision energy spread, 15 eV; cycle time, 550 ms; Q1 window, 20 Da; SWATH mass range, m/z 300-1100; number of SWATH experiments, 40; MS2 mass range: m/z 80-1100. Other parameters were curtain gas, 35; ion source gas 1, 60; ion source gas 2, 60; temperature, 350°C; ion spray voltage floating, 4.5 kV; declustering potential, 80 V. For ESI(-), the SWATH parameters were MS1 accumulation time, 100 ms; MS1 mass range, m/z 100-1700; MS2 accumulation time, 10 ms; collision energy, -50 eV; collision energy spread, 10 eV; cycle time, 550 ms; Q1 window, 15 Da; SWATH mass range, m/z 400-1000; number of SWATH experiments, 40; MS2 mass range: m/z 80-1000. Other parameters were curtain gas, 35; ion source gas 1, 60; ion source gas 2, 60; temperature, 350°C; ion spray voltage floating, -4.5 kV; declustering potential, -80 V. The mass calibration was automatically performed using an APCI positive/negative calibration solution via a calibration delivery system (CDS). n via a calibration delivery system (CDS).
MS ID MS08  +
MS Instrument LC, Agilent 1290 system; MS, AB Sciex TripleTOF 6600 system  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title Method 8: SCIEX TripleTOF 6600 SWATH for NIST SRM 1950 human plasma  +
Modification dateThis property is a special property in this wiki. 26 December 2019 06:26:47  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox