MS Description Sample Preparation Tryacylglycerols (TAGs Sample Preparation Tryacylglycerols (TAGs) in C57BL/6 mouse (purchased from SLC, Shizuoka, Japan) liver (100 mg) and white adipose tissue (WAT) (100 mg) were extracted using Bligh and Dyer's method in the following procedure: the liver and WAT were homogenized with 6 mL chloroform/methanol (1:2) for 10 strokes and left for 1 h at room temperature. Each phase separation was achieved by adding 2 mL chloroform and 2 mL water. After vortexing, the mixture was centrifuged at 3000 rpm for 10 min. The bottom organic layer containing the total lipid extract was collected and dried under a gentle stream of nitrogen, and then dissolved in chloroform / methanol (2:1) at a concentration of 10 ug (tissue weight) /uL. LC conditions Reverse-phased LC separation was achieved using ACQUITY UPLC BEH column (1.0 mm×150 mm i.d., particle size 1.7 um, Waters Corporation, Milford, MA, USA) at 45C. The mobile phase was acetonitrile / methanol / water : 19 / 19 / 2 (0.1% acetic acid + 0.028% ammonia) (A), and isopropanol (0.1% acetic acid + 0.028% ammonia) (B), and the composition was produced by mixing these solvents. The gradient consisted of holding solvent (A/B:90/10) for 5 min, then linearly converting to solvent (A/B:60/40) for 35 min and then linearly converting solvent (A/B:45/55) for 50 min. The mobile phase was pumped at a flow rate of 50 uL/min and the column pressure was adjusted lower than 5000 psi. Typically, 2 uL of sample solution was injected. ESI-MS conditions The ESI-MS analysis was performed using a quadrapole/time of flight hybrid mass spectrometer (QTOF microTM, Micromass, Manchester, UK) with an ACQUITY UPLC system (Waters Corporation). The mass range of the instrument was set at m/z 200–1100 and scan duration of MS and MS/MS at 0.5 s in positive ion mode. The capillary voltage was set at 3.5 kV, cone voltage at 30V, and source block temperature at 100C. The collision gas used for MS/MS experiments was argon (7.5×10E5 mbar), and the collision energy was set at 30 V. and the collision energy was set at 30 V.
MS ID MS1  +
MS Instrument ACQUITY UPLC system (Waters Corporation), QTOF micro (Micromass)  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive  +
MS Ionization ESI  +
MS Title ESI positive LC-MS analysis of triacylglycerols (TAG)  +
Modification dateThis property is a special property in this wiki. 1 April 2013 06:34:53  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox