SE110:/MS2
MS Comment of details Last update, Oct 3, 2016
MS Description The liquid chromatography system consisted The liquid chromatography system consisted of a Waters Acquity UPLC system (Waters Inc.). Mobile phase A was 1:1:3 acetonitrile:methanol:water (v/v/v) with 5 mM ammonium acetate and 10 nM EDTA. Mobile phase B was 100% isopropanol with 5 mM ammonium acetate and 10 nM EDTA. The LC column was an Acquity UPLC Peptide BEH C18 column (50×2.1 mm; 1.7 μm; 130Å). The gradient was 0 min, 0% B; 1 min, 0% B; 5 min, 40% B; 7.5 min, 64% B; 12.0 min, 64% B; 12.5 min, 82.5% B, 19 min, 85% B; 20 min, 95% B; 20.1 min, 0% B; 25 min, 0% B. The column flow rate was 0.3 mL/min, the autosampler temperature was 5°C, the injection volume was 1 uL for mouse liver tissue and 2 μL for the other samples. The column temperature was 45°C. MS was performed on an AB Sciex TripleTOF 5600+ system (Q-TOF) equipped with a DuoSpray ion source. All analyses were performed in the high sensitivity mode for both TOF-MS and product ion scanning. Mass calibration was automatically performed every five injections using an APCI positive/negative calibration solution and a calibration delivery system (CDS). Data-dependent MS/MS acquisition (DDA) was used. The common parameters in both positive and negative ion mode were collision energy, 45 V; collision energy spread, 15 V; mass range, m/z 70-1250; curtain gas, 30; ion source gas 1, 50; ion source gas 2, 50; temperature, 500°C for mouse ear tissue and 300°C for the other samples; declustering potential, 80 V; RF transmission, default. The ion spray voltage floating in positive/negative ion mode was +5.5/–4.5 kV, respectively. The DDA parameters in both positive and negative ion mode were MS1 accumulation time, 250 ms; MS2 accumulation time, 100 ms; cycle time, 1,300 ms; dependent product ion scan number, 10; intensity threshold, 100; exclusion time of precursor ion, 5 sec; mass tolerance, 20 mDa; ignore peaks, within 6 Da; dynamic background subtraction, TRUE. Da; dynamic background subtraction, TRUE.
MS ID MS2  +
MS Instrument LC, a Waters Acquity UPLC system; MS, an AB Sciex TripleTOF 5600+ system (Q-TOF) equipped with a DuoSpray ion source  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title LC-ESI-QTOFMS for untargeted lipidomics (both positive and negative ion modes)  +
Modification dateThis property is a special property in this wiki. 3 October 2016 09:08:30  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox