SE168:/MS01
MS Description Extraction of metabolites<br /> The Extraction of metabolites<br /> The freeze-dried samples were extracted with 50 μL of 80 % MeOH containing 2.5 μM 10-camphorsulfonic acid, 1.25 μM reserpine, 2.5 μM ampicillin, and 2.5 μM CHAPS as internal standards for calibration per mg dry weight using a mixer mill (MM300, Retsch) with zirconia beads for 7 min at 18 Hz and 4 °C. After 10 min of centrifugation, the supernatant was filtered with an HLB μElution plate (Waters). Extracts were routinely diluted with 80 % MeOH at a ratio of 1:1000 (extract: 80 % MeOH).<br /><br /> Direct infusion analysis<br /> Ultra-high-resolution metabolome data were acquired using an FTICR-MS solariX 7.0 T (Bruker Daltonics) with an ESI source. The following settings were applied: MS Detection; Acquisition Mass Control (mass range, m/z 100–800; estimated resolution power, 530,000 at m/z 400; transient length, 3.9147 s); Data Storage (save full profile spectrum, on; save FID file, on); Accumulation (scan time, 100; source accumulation, 0.01 s; ion accumulation time, 0.1 s; ion cooling time, 0 s; time of flight, 0.45 s); API Source (source type, ESI; capillary, 4500 V; end plate offset, 1000 V); Source Gas Tune (nebulizer 1.0 bar; dry gas, 2.0 L/min; dry temperature, 200 °C); Source Optics (capillary exit, −220 V; deflector plate, −200 V; funnel 1, −150 V; skimmer 1, −25 V; funnel RF amplitude, 180 Vpp); Octopole (frequency, 5 MHz; RF amplitude, 350 Vpp); Collision Cell (collision voltage, 0.8 V; DC extract bias, −0.9 V; RF frequency, 2 MHz; collision RF amplitude, 850 Vpp); Transfer Optics (time of flight, 0.45 ms; frequency, 6 MHz; RF amplitude, 400 Vpp); Infinity Cell (transient exit lens, 20 V; analyzer entrance, 10 V; side kick, 0 V; side kick offset, 1.5 V; front trap plate, −0.5 V; back trap plate, −0.5 V; sweep excitation power, 20 %); Multiple Cell Accumulations (number of ICR cell fills, 1); Gated Trapping (gated trapping mode, off); Polarity, negative. MS spectra were internally calibrated using the MS spectra of internal standards. sing the MS spectra of internal standards.
MS ID MS01  +
MS Instrument FTICR-MS solariX 7.0 T (Bruker Daltonics)  +
MS Ion Mode negative  +
MS Ionization ESI  +
MS Title FTICR-MS (Direct infusion)  +
Modification dateThis property is a special property in this wiki. 14 May 2018 06:24:05  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox