MS Description - Extraction Frozen soil sample (300 mg) - Extraction Frozen soil sample (300 mg) was extracted with 900 µL of methanol containing 25 µM of 7-hydroxy-5-methylflavone as an internal standard. After homogenizing the samples by mixing twice for 2 min each time using a Mixer Mill MM 300 (QIAGEN K.K., Tokyo, Japan) at 25 Hz, the homogenates were centrifuged (17,400 xg for 5 min at 4C). After recovery of the supernatant from each homogenate, it was filtered through a 0.2-µm polytetrafluoroethylene (PTFE) membrane (Millipore). Hydrophobic compounds in the filtrate were removed by absorption to a C18 silica column (MonoSpin C18, GL Science, Tokyo, Japan). The eluate was used for the untargeted metabolome analysis using LC-MS. Mock samples were prepared as above without adding the soil materials. - LC-MS The untargeted metabolome analysis was performed using an Agilent 1100 system (Agilent, Palo Alto, CA) coupled to a Finnigan LTQ-FT (Thermo Fisher Scientific). An aliquot (20 µL) of a methanol solution was applied to a TSK-gel column ODS-100V (4.6 x 250 mm, 5 µm; TOSOH Corporation, Tokyo, Japan). Water (HPLC grade; solvent A) and acetonitrile (HPLC grade; solvent B) were used as the mobile phase with 0.1% v/v formic acid added to both solvents. The gradient program was as follows: 3% B (0 min), 97% B (90 min), 97% B (100 min), 3% B (100.1 min) and 3% B (107 min). The flow rate was set to 0.25 mL/min (0–100 min) and 0.5 mL/min (100.1–107 min). The column oven temperature was set to 40C. The mass range was m/z 100–1500. The electrospray-ionization (ESI) settings were a spray voltage of 4.0 kV and capillary temperature of 300 °C. The nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively. The MSn analysis was performed with ESI positive mode as follows: Full mass scan with FT-ICR at a resolution of 100,000 and a mass scan range 100-1500, and MS2 scans by collision-induced dissociation for the most intense five ions of the full mass scan with ion trap (IT). To monitor the HPLC eluate, a photodiode array detector was used with a wavelength range of 200–650 nm. Data were acquired and browsed using Xcalibur software version 2.0.7 (Thermo Fisher Scientific). version 2.0.7 (Thermo Fisher Scientific).
MS ID MS1  +
MS Instrument Agilent1200 HPLC (Agilent), LTQ-FT (Thermo Fisher Scientific)  +
MS Instrument Type LC-FTICR-MS  +
MS Ion Mode Positive  +
MS Ionization ESI  +
MS Title LC-FTICR-MS, ESI Positive  +
Modification dateThis property is a special property in this wiki. 10 August 2019 11:29:13  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox