MS Description Methanol, isopropanol, and acetonitrile of Methanol, isopropanol, and acetonitrile of LC-MS grade were purchased from Wako. Ammonium formate and formic acid were purchased from Wako. Water was purchased from Millipore. <LC Method> The LC system consisted of a Bruker Elute UHPLC system. Lipids were separated on an Acquity UPLC HSS T3 C18 column (50 x 1.0 mm; 1.8 µm) (Waters, Milford, MA, USA). The column was maintained at 55°C at a flow-rate of 0.15 mL/min. The mobile phases consisted of (A) 200:800:10:1 (v/v/v/v) acetonitrile:water:1M ammonium formate:formic acid and (B) 100:900:10:1 (v/v/v/v) acetonitrile:isopropanol:1M ammonium formate:formic acid. A sample volume of 2 µL was used for the injection. The separation was conducted under the following gradient: 0 min 35% (B); 3 min 70% (B); 7 min 85% (B); 10 min 90% (B); 12 min 90% (B); 12.5 min 35% (B); and 15 min 35% (B). Sample temperature was maintained at 10°C. <MS Method> Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). The PASEF mode acquisition, i.e. data dependent MS/MS acquisition with the ion mobility separation, was performed by the following parameters. The parameters were MS1 mass ranges, m/z 200-1600 and MS2 mass ranges, m/z 50-1600; MS1 and MS2 accumulation time, 148.5 ms; mobility range 0.55-1.9; collision energy 30 eV; end plate offset, 500 V; capillary voltage, +4.2/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 8.0 l/min; dry temperature, 200°C; funnel 1 RF (radio frequency), 300 Vpp; funnel 2 RF, 250 Vpp; multipole RF, 200 Vpp; deflection delta, 70 V; quadrupole ion energy, 5 eV; collision transfer energy, 15 eV; collision RF, 1100 Vpp; transfer time 54 µs; pre-pulse storage, 5 µs; tims transfer Δ1, -20 V/+20 V; tims transfer Δ2, -120 V/+120 V; tims transfer Δ3, +70 V/-70 V; tims transfer Δ4, +100 V/-100 V; tims transfer Δ5, 0 V; tims transfer Δ6, +100 V/-100 V; intensity threshold, 2500 cts; target intensity, 20000 cts; exclusion time of precursor ion, 0.1 min. The mass calibration was automatically performed using 5 mM sodium formate calibration solution. 5 mM sodium formate calibration solution.
MS ID MS04  +
MS Instrument LC, Bruker Elute UHPLC system; MS, Bruker timsTOF Pro  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title Method 4: Bruker timsTOF Pro PASEF for plant lipidomics  +
Modification dateThis property is a special property in this wiki. 26 December 2019 06:23:23  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox