Sample Set Information

ID SE196
Title A lipidome atlas in MS-DIAL 4
Description We formulated mass spectral fragmentations of lipids across 117 lipid subclasses and included ion mobility tandem mass spectrometry (MS/MS) to provide a comprehensive lipidome atlas with retention time, collision cross section and MS/MS information. Using human, murine, algal, and plant biological samples, we annotated and semi-quantified 8,051 lipids by MS-DIAL 4 (http://prime.psc.riken.jp/) with a 1–2% estimated false discovery rate, using the lipidomics standards initiative level 2 or 3 definitions.
Authors Hiroshi Tsugawa, Kazutaka Ikeda, Mikiko Takahashi, Aya Satoh, Yoshifumi Mori, Haruki Uchino, Nobuyuki Okahashi, Yutaka Yamada, Ipputa Tada, Paolo Bonini, Yasuhiro Higashi, Yozo Okazaki, Zhiwei Zhou, Zheng-Jiang Zhu, Jeremy Koelmel, Tomas Cajka, Oliver Fiehn, Kazuki Saito, Masanori Arita, and Makoto Arita
Reference Tsugawa, H. et al. A lipidome atlas in MS-DIAL 4. Nat Biotechnol (2020). https://doi.org/10.1038/s41587-020-0531-2
Comment


Link icon database.png Link icon dropmet.png

The raw data files are available at DROP Met web site in PRIMe database of RIKEN.

Link icon article.png

Analytical Method Details Information

ID MS07
Title Method 7: Waters XevoG2 QTOF DDA for plant lipidomics
Instrument LC, Waters Acquity UPLC system; MS, Waters Xevo G2 QTOF MS
Instrument Type UPLC-QTOF-MS
Ionization ESI
Ion Mode Positive and Negative
Description Methanol, isopropanol, and acetonitrile of LC-MS grade were purchased from Wako. Ammonium acetate, formic acid, methyl tert-butyl ether (MTBE), and water were also purchased from Wako. 1,2-Didecanoyl-sn-glycero-3-phosphocholine used for the internal standard was purchased from Sigma-Aldrich.

<LC Method>

The LC system consisted of a Waters Acquity UPLC system. Lipids were separated on the mostly same condition as described in Method 3 except for using ammonium acetate instead of ammonium formate. The LC system consisted of a Waters Acquity UPLC system. Lipids were separated on an Acquity UPLC HSS T3 C18 column (50 x 1.0 mm; 1.8 µm) (Waters, Milford, MA, USA). The column was maintained at 55°C at a flow-rate of 0.15 mL/min. The mobile phases consisted of (A) 200:800:10:1 (v/v/v/v) acetonitrile:water:1 M ammonium acetate:formic acid and (B) 100:900:10:1 (v/v/v/v) acetonitrile:isopropanol:1 M ammonium acetate:formic acid. A sample volume of 1 µL was used for the injection. The separation was conducted under the following gradient: 0 min 35% (B); 3 min 70% (B); 7 min 85% (B); 10 min 90% (B); 12 min 90% (B); 12.5 min 35% (B); and 15 min 35% (B). Sample temperature was maintained at 10°C.

<MS Method>

Mass spectrometric detection of lipids was performed on a quadrupole/time-of-flight mass spectrometer Xevo G2 QTOF MS (Waters, Milford, MA, USA). MS2 analyses were performed at the sensitivity mode. Data dependent MS/MS acquisition (DDA) was used for MS2. The conditions for recording were as follows: source capillary, 3.0 (positive ion mode) and 2.5 kV (negative ion mode); sampling cone, 20 (positive) and 40 (negative); extraction cone, 4.0; source temperature, 120°C; desolvation temperature, 450°C; cone gas flow, 50 L/h; desolvation gas flow, 600 L/h; scan ranges, m/z 100-1600; MS1 scan time, 200 ms (centroid); MS2 scan time, 100 ms (centroid); collision energy, 20-50 eV (ramp mode). The other DDA parameters were event number, 6; scan repeat, 3; peak selection mode to trigger MS/MS, intensity-based detection; deisotope peak detection, yes; ionization mode, ESI; and correction by lock mass function, yes.