Sample Set Information

ID SE196
Title A lipidome atlas in MS-DIAL 4
Description We formulated mass spectral fragmentations of lipids across 117 lipid subclasses and included ion mobility tandem mass spectrometry (MS/MS) to provide a comprehensive lipidome atlas with retention time, collision cross section and MS/MS information. Using human, murine, algal, and plant biological samples, we annotated and semi-quantified 8,051 lipids by MS-DIAL 4 (http://prime.psc.riken.jp/) with a 1–2% estimated false discovery rate, using the lipidomics standards initiative level 2 or 3 definitions.
Authors Hiroshi Tsugawa, Kazutaka Ikeda, Mikiko Takahashi, Aya Satoh, Yoshifumi Mori, Haruki Uchino, Nobuyuki Okahashi, Yutaka Yamada, Ipputa Tada, Paolo Bonini, Yasuhiro Higashi, Yozo Okazaki, Zhiwei Zhou, Zheng-Jiang Zhu, Jeremy Koelmel, Tomas Cajka, Oliver Fiehn, Kazuki Saito, Masanori Arita, and Makoto Arita
Reference Tsugawa, H. et al. A lipidome atlas in MS-DIAL 4. Nat Biotechnol (2020). https://doi.org/10.1038/s41587-020-0531-2
Comment


Link icon database.png Link icon dropmet.png

The raw data files are available at DROP Met web site in PRIMe database of RIKEN.

Link icon article.png

Sample Information

ID S35
Title 35_51_Mouse_Heart (Bruker Mouse tissues)
Organism - Scientific Name Heart (Mouse)
Organism - ID NCBI taxonomy 10090
Compound - ID
Compound - Source
Preparation
Sample Preparation Details ID
Comment

Analytical Method Information

ID M02
Title 51_Bruker Mouse tissues: Heart (Mouse) LC-ESI-MS analysis (PASEF)
Method Details ID MS06
Sample Amount Positive mode: 1 microLiter; Negative mode: 2 microLiter
Comment


Analytical Method Details Information

ID MS06
Title Method 6: Bruker timsTOF Pro PASEF for mouse tissue lipidomics
Instrument LC, Bruker Elute UHPLC system; MS, Bruker timsTOF Pro
Instrument Type UPLC-QTOF-MS
Ionization ESI
Ion Mode Positive and Negative
Description Methanol, isopropanol, and acetonitrile of LC-MS grade were purchased from Wako. Ammonium acetate and EDTA were purchased from Wako and Dojindo, respectively. Milli-Q water was purchased from Millipore.

<LC Method>

The LC system consisted of a Bruker Elute UHPLC system. Lipids were separated on an Acquity UPLC Peptide BEH C18 column (50 x 2.1 mm; 1.7 µm) (Waters, Milford, MA, USA). The column was maintained at 45°C at a flow-rate of 0.3 mL/min. The mobile phases consisted of (A) 1:1:3 (v/v/v) acetonitrile:methanol:water with ammonium formate (5 mM) and 10 nM EDTA and (B) 100% isopropanol with ammonium formate (5 mM) and 10 nM EDTA. A sample volume of 0.5-3 µL, which depended on biological samples, was used for the injection. The separation was conducted under the following gradient: 0 min 0% (B); 1 min 0% (B); 5 min 40% (B); 7.5 min 64% (B); 12 min 64% (B); 12.5 min 82.5% (B); 19 min 85% (B); 20 min 95% (B); 20.1 min 0% (B); and 25 min 0% (B). Sample temperature was maintained at 4°C.

<MS Method>

Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). Data dependent MS/MS acquisition (DDA) was used. The parameters were MS1 and MS2 mass ranges, m/z 50-2500; MS1 and MS2 accumulation time, 100 ms; mobility range, 0.55-1.90; collision energy 30 eV; end plate offset, 500 V; capillary voltage, +4.5 kV/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 10.0 L/min; dry temperature, 220°C; funnel 1 RF, 300 Vpp; funnel 2 RF, 200 Vpp/250 Vpp; multipole RF, 200 Vpp; deflection delta, 70 V/-70 V; quadrupole ion energy, 6 eV/5 eV; collision transfer energy, 14 eV/15 eV; collision RF, 1500 Vpp/1100 Vpp; transfer time 75 µs/54 µs; pre-pulse storage, 10 µs/5 µs; tims transfer Δ1, -20 V/20 V; tims transfer Δ2, -120 V/120 V; tims transfer Δ3, 70 V/-70 V; tims transfer Δ4, 100 V/-100 V; tims transfer Δ5, 0 V; tims transfer Δ6, 100 V/-100 V; intensity threshold, 250 cts.; target intensity, 4000 cts; exclusion time of precursor ion, 0.1 min. The mass calibration was automatically performed using 5 mM sodium acetate calibration solution. For the confirmation of ESI(+)-MS/MS spectra for phosphatidylcholine, the positive ion mode data was acquired with the following setting. The parameters were dry temperature, 200°C; funnel 2 RF, 250 Vpp; quadrupole ion energy, 5 eV; collision transfer energy, 15 eV; collision RF, 1100 Vpp; and transfer time 54 µs; pre-pulse storage, 5 µs. The other parameters were the same as above.

Comment_of_details