MS Description Methanol, isopropanol, and acetonitrile of Methanol, isopropanol, and acetonitrile of LC-MS grade were purchased from Wako. Ammonium acetate, formic acid, methyl tert-butyl ether (MTBE), and water were also purchased from Wako. 1,2-Didecanoyl-sn-glycero-3-phosphocholine used for the internal standard was purchased from Sigma-Aldrich. <LC Method> The LC system consisted of a Waters Acquity UPLC system. Lipids were separated on the mostly same condition as described in Method 3 except for using ammonium acetate instead of ammonium formate. The LC system consisted of a Waters Acquity UPLC system. Lipids were separated on an Acquity UPLC HSS T3 C18 column (50 x 1.0 mm; 1.8 µm) (Waters, Milford, MA, USA). The column was maintained at 55°C at a flow-rate of 0.15 mL/min. The mobile phases consisted of (A) 200:800:10:1 (v/v/v/v) acetonitrile:water:1 M ammonium acetate:formic acid and (B) 100:900:10:1 (v/v/v/v) acetonitrile:isopropanol:1 M ammonium acetate:formic acid. A sample volume of 1 µL was used for the injection. The separation was conducted under the following gradient: 0 min 35% (B); 3 min 70% (B); 7 min 85% (B); 10 min 90% (B); 12 min 90% (B); 12.5 min 35% (B); and 15 min 35% (B). Sample temperature was maintained at 10°C. <MS Method> Mass spectrometric detection of lipids was performed on a quadrupole/time-of-flight mass spectrometer Xevo G2 QTOF MS (Waters, Milford, MA, USA). MS2 analyses were performed at the sensitivity mode. Data dependent MS/MS acquisition (DDA) was used for MS2. The conditions for recording were as follows: source capillary, 3.0 (positive ion mode) and 2.5 kV (negative ion mode); sampling cone, 20 (positive) and 40 (negative); extraction cone, 4.0; source temperature, 120°C; desolvation temperature, 450°C; cone gas flow, 50 L/h; desolvation gas flow, 600 L/h; scan ranges, m/z 100-1600; MS1 scan time, 200 ms (centroid); MS2 scan time, 100 ms (centroid); collision energy, 20-50 eV (ramp mode). The other DDA parameters were event number, 6; scan repeat, 3; peak selection mode to trigger MS/MS, intensity-based detection; deisotope peak detection, yes; ionization mode, ESI; and correction by lock mass function, yes. and correction by lock mass function, yes.
MS ID MS07  +
MS Instrument LC, Waters Acquity UPLC system; MS, Waters Xevo G2 QTOF MS  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title Method 7: Waters XevoG2 QTOF DDA for plant lipidomics  +
Modification dateThis property is a special property in this wiki. 26 December 2019 06:25:44  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox